Contact us on +39 0322 96142 or info@effecto.com

Medium Duty Fluid/Coolant Modules

Medium Duty Fluid/Coolant Modules

XCHANGE™ Utility Module

Medium Duty Fluid/Coolant Modules

These Modules pass fluid during an automatic tool changing operation.

Advantages

• Flexible Connection Options
• Valved/Checked interface on both Robot and Tool Adaptors
• Clear indication of supply/return lines
o AIR, WATER IN, WATER OUT
• Extended Fittings to seal connection prior to flow of fluid

Datasheet ModelCompatible XCHANGE™
Tool Changers
Number of
User Connections
LabelWeight

kg (lb)
User Interface*Flow

Cv
User Pressure Range

bar (psi)
Coolant Module – E80/100 E80 and E1002WATER IN
and WATER OUT
0.60
(1.32)
¼” BSPP1.540 – 7
(0 – 101)
Coolant Module – E125LP E125LP2WATER IN
and WATER OUT
0.66
(1.46)
¼” BSPP1.540 – 7
(0 – 101)
Fluid Module – E80/100 E80 and E1003AIR, WATER IN,
and WATER OUT
0.84
(1.85)
¼” BSPP1.540 – 7
(0 – 101)
Fluid Module – E125LPE125LP3AIR, WATER IN,
and WATER OUT
0.90
(1.98)
¼” BSPP1.540 – 7
(0 – 101)

* Application specific fittings or threads available upon request.
Operating Temperature 5 - 60 °C (40 - 140 °F)
Noise Emissions (Sound Pressure) ≤ 70 dB(A) in any direction

The dimensions are indicative and susceptible to changes due to technical improvements. We reserve the right to make changes without notice.

FLOW FORMULAS

Imperial measurement units:

Flow of Gases (Pneumatic Module)                                                                                                                                Flow of Fluids (Coolant Module)

QG = Gas flow rate in Standard Cubic Feet per Hour (SCFH)
Q = Valve flow rate in gallons per minute (US gpm)
Cv = Flow Coefficient = 1.54 for these modules
P1 = Upstream (inlet) absolute pressure in pounds per square inch (psi)
P2 = Downstream (outlet) absolute pressure in pounds per square inch (psi)
GG = Specific gravity of medium where air at 70°F and 14.7 psia equals 1.0
GF = Specific gravity of fluid related to water
T = Absolute temperature in °R (°F + 460)

Metric measurement units:

Flow of Gases (Pneumatic Module)                                                                                                                               Flow of Fluids (Coolant Module)

QG = Gas flow rate in Standard Cubic Meters per Hour (m3/h)
Q = Valve flow rate in Cubic Meters per Hour (m3/h)
Cv = Flow Coefficient = 1.54 for these modules
P1 = Upstream (inlet) absolute pressure in bar
P2 = Downstream (outlet) absolute pressure in bar
GG = Specific gravity of medium where air at 20°C and 1 bar equals 1.0
GF = Specific gravity of fluid related to water
T = Absolute temperature in °R (°F + 460)