Contact us on +39 0322 96142 or info@effecto.com

Heavy Duty Fluid/Coolant Modules

Heavy Duty Fluid/Coolant Modules

XCHANGE™ Utility Module

Heavy Duty Fluid/Coolant Modules

These Modules pass fluid during an automatic tool changing operation.

Advantages

• Flexible Connection Options
• Valved/Checked interface on both Robot and Tool Adaptors
• Clear indication of supply/return lines
o AIR, WATER IN, WATER OUT
• Coolant Modules have Extended Fittings to seal connection prior to flow of coolant

Datasheet ModelDescriptionUser ConnectionsUser Interface*FlowUser Pressure RangeWeight
S-EM-R-U-1V1/2xxxRobot - Pneumatic – Single
E125, E160, ES200, ES315
1½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.22 kg
S-EM-T-U-1V1/2xxxTool - Pneumatic – Single
E125, E160, ES200, ES315
1½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.22 kg
S-EM-R-U-2V1/2xxxRobot - Pneumatic – Double
E125, E160, ES200, ES315
2½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.33 kg
S-EM-T-U-2V1/2xxxTool - Pneumatic – Double
E125, E160, ES200, ES315
2½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.33 kg
S-EM-R-U-2VE1/2xxxRobot - Coolant – Double
E125, E160, ES200, and ES315
2½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.62 kg
S-EM-T-U-2VE1/2xxxTool - Coolant – Double
E125, E160, ES200, and ES315
2½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.62 kg
ER125-U-1V1/2xxxRobot - Pneumatic – E125
Tool - Pneumatic – E125
1½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.15 kg
ET125-U-1V1/2xxxTool - Pneumatic – E1251½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.15 kg
ER125-U-01VE-1/2xxx-B-WIRobot - Coolant WATER IN – E125 1½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.30 kg
ET125-U-01VE-1/2xxx-B-WITool - Coolant WATER IN – E1251½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.30 kg
ER125-U-01VE-1/2xxx-B-WORobot - Coolant WATER OUT – E1251½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.30 kg
ET125-U-01VE-1/2xxx-B-WOTool - Coolant WATER OUT – E1251½” BSPP or ½” NPT1.54 Cv0 – 7 bar0.30 kg

* Application specific fittings or threads available upon request.
Operating Temperature 5 - 60 °C (40 - 140 °F)
Noise Emissions (Sound Pressure) ≤ 70 dB(A) in any direction

The dimensions are indicative and susceptible to changes due to technical improvements. We reserve the right to make changes without notice.

FLOW FORMULAS

Imperial measurement units:

Flow of Gases (Pneumatic Module)                                                                                                                                Flow of Fluids (Coolant Module)

QG = Gas flow rate in Standard Cubic Feet per Hour (SCFH)
Q = Valve flow rate in gallons per minute (US gpm)
Cv = Flow Coefficient = 1.54 for these modules
P1 = Upstream (inlet) absolute pressure in pounds per square inch (psi)
P2 = Downstream (outlet) absolute pressure in pounds per square inch (psi)
GG = Specific gravity of medium where air at 70°F and 14.7 psia equals 1.0
GF = Specific gravity of fluid related to water
T = Absolute temperature in °R (°F + 460)

Metric measurement units:

Flow of Gases (Pneumatic Module)                                                                                                                               Flow of Fluids (Coolant Module)

QG = Gas flow rate in Standard Cubic Meters per Hour (m3/h)
Q = Valve flow rate in Cubic Meters per Hour (m3/h)
Cv = Flow Coefficient = 1.54 for these modules
P1 = Upstream (inlet) absolute pressure in bar
P2 = Downstream (outlet) absolute pressure in bar
GG = Specific gravity of medium where air at 20°C and 1 bar equals 1.0
GF = Specific gravity of fluid related to water
T = Absolute temperature in °R (°F + 460)